TE7: Continue machining at the contour (retrace support) - 840D sl only
19.5 RESU-specific part programs
RESET response
In reset events:
● NCK POWER ON RESET (warm start)
● NCK Reset
● End of program (M30)
CC_PREPRE(-1) is executed implicitly.
Error messages
The following programming errors are detected and displayed with alarms:
● Invalid mode programmed:
RESU alarm 75601 "Channel
● More than one parameter programmed:
Alarm 12340 "Channel
● RESU technology function is not available:
The technological function is not available. The compile cycle is possibly not loaded or it
was not activated.
Alarm 12340 "Channel
not available"
19.5
RESU-specific part programs
19.5.1
Overview
RESU uses the following, automatically generated and partially adjustable part programs:
Program
Main program
INI program
END program
Continue machining ASUB
RESU ASUB
The following figure provides an overview of the internal structure of the technological function
and the relationship between the various part programs.
712
number Block number Invalid parameter for CC_PREPRE( )"
number Block number Too many parameters"
number Block number Name CC_PREPRE not defined or option
Name
CC_RESU.MPF
CC_RESU_INI.SPF
CC_RESU_END.SPF
CC_RESU_BS_ASUP.SPF
CC_RESU_ASUP.SPF
Function Manual, 01/2015, 6FC5397-2BP40-5BA2
Special functions