K8: Geometric machine modeling - only 840D sl
6.2 Commissioning
Syntax
$NP_PROT_D_LEVEL[<m>] = <value>
Meaning
$NP_PROT_D_LEVEL:
<m>:
<value>:
Example
The 6th protection area is to be displayed as of detail level 3:
Program code
N100 $NP_PROT_D_LEVEL[5] = 3
6.2.3.8

$NP_BIT_NO

Function
Enter the bit number of an NC/PLC interface signal of the 64-bit wide interface with which the
protection area is to be connected in system variable $NP_BIT_NO. If the protection area is
not to be connected to an NC/PLC interface signal, enter the value -1.
NC/PLC interface
Activation / deactivation of the protection area can be requested via NC/PLC interface signals
via the PLC user program or this can be used for feedback on the current status to the PLC
user program:
● Requirement: DB10, DBX234.0 - DBX241.7 (Page 809)
● Feedback: DB10, DBX226.0 - DBX233.7 (Page 810)
Precondition
The status of the protection area must be "preactivated" or "PLC-controlled" in order for the
NC/PLC interface of the protection area to be observed. $NP_INIT_STAT (Page 230) == "P"
(preactivated or PLC-controlled)
228
Detail level for the protection area
Data type:
INT
Range of val‐
0 ≤ D ≤ 3
ues:
Default value:
0
System variable or protection area index
Data type:
INT
Range of val‐
0, 1, 2, ... ($MN_MM_3D_MAXNUM_PROT_AREAS - 1)
ues:
Detail level
Data type:
INT
Comment
; 6. Protection area,
; detail level = 3
Function Manual, 01/2015, 6FC5397-2BP40-5BA2