T4: Automatic retuning with AST - only 840D sl
12.3 Programming
Parameters
No.
Parameters
1
<S_I_ACTIONREQUEST>
Data type:
INT
Value:
0 =
1 =
2 =
2
<S_SZ_NAME>
Meaning:
The name of the restoration file in the file system (without path details!)
Data type:
STRING [100]
12.3.6

CYCLE756 - Activate optimization results

CYCLE756 activates the optimization results at a specific time / for specific conditions. The
conditions must be queried in the manufacturer cycle. CYCLE756 can also specify which
control parameters should be active: original data, axis-optimum data or path-optimum data.
Syntax
CYCLE756(<S_I_AXIS>, <S_I_REGULATOR_ROLE>, <S_B_SAVEBOOTFILES>)
Parameters
No.
Parameters
1
<S_I_AXIS>
Meaning:
Machine axis number
Data type:
INT
524
Not defined
Backup data for a later restore
This setting saves the data values at the time of the cycle call in the specified file.
The content of the data backup is determined by the following parameters:
- the current valid optimization strategy
- the axes currently added to the optimization session
- the current list of parameter sets to be overwritten
Restore data
This setting restores the data from the specified file.
Requirements:
● The optimization session is still active.
● The axis and data set selection at the time of the backup is still available.
Function Manual, 01/2015, 6FC5397-2BP40-5BA2
Special functions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828dSinumerik 840de sl