BSlow Blow Fuse
Slow blow fuse is provided to protect the electrical circuits.
If the slow blow fuse is blown, check the electrical circuits
for trouble and then replace with a new compatible slow
blow fuse.
(1) Slow blow fuse
(1) Slow blow fuse
[Open cab model]
Protected circuit
(A)
Main [60A]
Alternator [SSV65: 80A]
(B)
[SSV75: 100A]
(C)
CRS [30A]
(D)
Glow CAB [60A]
[Closed cab model]
Protected circuit
(A) Main [60A]
(B) Alternator [100A]
(C) CRS [30A]
(D) Glow CAB [60A]
OTHER ADJUSTMENTS AND REPLACEMENTS
C Replacement procedure
[Bolted slow blow fuse]
1. Disconnect the negative cord of the battery.
2. Remove the slow blow fuse case.
(1) Slow blow fuse case
3. Open the slow blow fuse case cap and cover then
remove the bolts and draw out the bolted slow blow
fuse.
(1) Slow blow fuse case cap
(2) Cover
(3) Bolt
Fuse type
(4) Bolted slow blow fuse
Bolted
Bolted
Plug-in
Plug-in
Fuse type
Bolted
Bolted
Plug-in
Plug-in
83