Replacing Slow-Blow Fuses - Kubota RTV400 Operator's Manual

Table of Contents

Advertisement

C Protected circuit
Fuse
Capacity
No.
(A)
1
15
Head lamp, Tail lamp, Panel
2
10
3
5
4
---
5
15
6
10
Regulator, (Work light relay), (AUX (KEY ON))
7
5
8
10
9
15
10
15
11
---
12
5, 10, 15
Protected circuit (OLD)
Eng. control, Fuel pump
Starter
---
(Hazard)
Panel
12V DC output
Brake lamp, Horn
(Work light)
Fuse puller
Spare
BReplacing Slow-Blow Fuses
The slow-blow fuses are intended to protect the electrical
cabling. If any of them have blown out, be sure to pinpoint
the cause. Never use any substitute, use only a KUBOTA
genuine part.
C Replacement procedure
1. Disconnect the negative cable of the battery.
2. Remove the cover and the slow-blow fuse box cover.
3. Pull out the slow-blow fuse.
4. Insert a new slow-blow fuse into the slow-blow fuse
box.
5. Install the slow-blow fuse box cover.
6. Connect the negative battery cable.
(1) Slow-blow fuse box
C Protected circuit
Fuse No.
Capacity (A)
1
Slow-blow fuse (30)
2
Slow-blow fuse (50)
PERIODIC SERVICE
Protected circuit
Key switch
Regulator
63