62
MAINTENANCE
C How to read the indicator
Check the battery condition by reading the indicator.
State of indicator display
Specific gravity of electrolyte and quality of
Green
electrolyte are both in good condition.
Black
Needs charging battery.
White
Needs replacing battery.
C Battery Charging
To avoid personal injury or death:
A When the battery is being activated, hydrogen
and oxygen gases in the battery are extremely
explosive. Keep open sparks and flames away
from the battery at all times, especially when
charging the battery.
A When charging the battery, ensure the vent
caps are securely in place. (if equipped)
A When disconnecting the cable from the battery,
start with the negative terminal first.
When connecting the cable to the battery, start
with the positive terminal first.
A Never check battery charge by placing a metal
object across the posts.
Use a voltmeter or hydrometer.
When attaching the new battery, its positve terminal faces
to the rearward of the machine.
(1) Battery
(2) Positive terminal
1. To slow charge the battery, connect the battery
positive terminal to the charger positive terminal and
the negative to the negative, then recharge in the
standard fashion.
(A) Rearward of the machine
2. A boost charge is only for emergencies. It will partially
charge the battery at a high rate and in a short time.
When using a boost-charged battery, it is necessary to
recharge the battery as early as possible.
Failure to do this will shorten the battery's service life.
3. The battery is charged if the indicator display turns
green from black.
4. When replacing an old battery, make sure the new one
is of equal specification.
Battery Type
Volts (V)
GP31(105E41R)
12
C Direction for Storage
1. When storing the machine for long periods of time,
remove the battery from machine, adjust the
electrolyte to the proper level and store in a dry place
out of direct sunlight.
2. The battery self-discharges while it is stored.
Recharge it once every three months in hot seasons
and once every six months in cold seasons.
BChecking Air-Conditioner Condenser
Check air-conditioner condenser to be sure it is clean from
debris.
(1) Air-conditioner condenser
A Air flows through the condenser, entering through the
top and exiting out the bottom. As such debris may
accumulate on the top side. Remove the outside cover
to gain better access for cleaning.
Capacity
85.3 (at 5H.R(A.H))