Replacing Slow-Blow Fuses - Kubota RTV900 Operator's Manual

Hide thumbs Also See for RTV900:
Table of Contents

Advertisement

82
PERIODIC SERVICE
(1) Cover
(2) Fuse box cover
(3) Slow-blow fuse box cover
(1) Fuse puller
(2) Fuse
C Protected circuit
Fuse No.
Capacity (A)
1
Slow-blow fuse (50)
2
Slow-blow fuse (60)
3
15
4
5
5
10
6
20
7
15
8
15
9
5
10
10
11
10
12
15
13
---
14
5, 10, 15, 20
15 *
20
* Hydraulic utility valve equipped model
BReplacing Slow-Blow Fuses
The slow-blow fuses are intended to protect the electrical
cabling. If any of them have blown out, be sure to pinpoint
the cause. Never use any substitute, use only a KUBOTA
genuine part.
C Replacement procedure
1. Disconnect the negative cable of the battery.
2. Remove the cover and the slow-blow fuse box cover.
3. Pull out the slow-blow fuse.
4. Insert a new slow-blow fuse into the slow-blow fuse
box.
5. Install the slow-blow fuse box cover and the cover.
6. Connect the negative battery cable.
Protected circuit
Key switch
Alternator
Head lamp,
Tail lamp, Panel
Glow lamp
(Hazard)
Fan motor
Eng. Stop
Alternator, Brake lamp,
Fan motor relay
Panel,
Eng. Stop control
12V DC output
Horn
(Work light)
Fuse puller
Spare
Oil cooler fan motor

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents