74
REGULAR CHECKS AND MAINTENANCE WORK
BChanging Return Filter (First filter change:
250 hours)
See "Hydraulic Oil Change (Including Replacing Suction
Filter in the Hydraulic Tank and Return Filter)" in "EVERY
1000 SERVICE HOURS" in "REGULAR CHECKS AND
MAINTENANCE WORK" section.
(1) Hydraulic oil filter (return)
BReplacing Breather Filter
The breather filter for the hydraulic tank is located above
the hydraulic tank
1. Raise the cab. (See "Tilting Up the CAB" in "OPENING
AND
CLOSING
"MAINTENANCE" section for detail.)
2. Open the cap of the filter cover.
3. Remove the breather filter and replace with the new
one.
4. Tighten the cap of the filter cover.
(1) Breather filter
OF
COMPONENTS"
BReplacing Hydraulic Oil Filter (First filter
change: 50 hours)
1. Raise the cab. (See "Tilting the CAB" in "OPENING
AND CLOSING OF PARTS" in "MAINTENANCE"
section for detail.)
2. Remove the hydraulic oil filter with the wrench and
Replace with the new one.
3. Oil the O-ring of the new hydraulic filter cartridge
lightly.
Then tighten the hydraulic filter cartridge by hand.
(1) Hydraulic oil filter
BChecking Air-conditioner Drain
in
Check the air-conditioner unit cover to see if its drain hose
end is clogged with dust and other foreign matters.
(1) Air-conditioner unit cover
(2) Air-conditioner drain