60
MAINTENANCE
A As water is collected, the red float goes up.
When the float has reached the specified line,
immediately drain the water separator.
A In reattaching the water separator, be careful to keep
off dust and dirt.
A Be sure to purge the fuel system before getting the
machine restarted.
(See "PURGING OF THE FUEL SYSTEM" in
"OTHER
CHECKS
section.)
A If the water separator error code (E: 9120) appears on
the meter panel, immediately drain the water
separator.
BChecking Evacuator Valve
Open the evacuator valve to get rid of large particles of
dust and dirt.
(1) Evacuator valve
A If the evacuator valve is missing or damaged, the air
cleaner does not function properly. Accordingly, its
element's service life will get shorter.
BChecking Air Cleaner Warning Indicator
If the air cleaner is clogged, the air cleaner warning
indicator on the instrument panel will light up.
If this should happen at high engine rpm, stop the engine
and clean the air cleaner element.
(See "Inspection and Cleaning Air Cleaner Element", "Air
Cleaner Element" and "Cleaning Evacuator Valve" in
"EVERY 50 SERVICE HOURS" in "REGULAR CHECKS
AND MAINTENANCE WORK" section.)
AND
REPLACEMENTS"
(1) Air cleaner warning indicator
BChecking Diesel Particulate Filter (DPF)
Muffler
To avoid personal injury or death:
A Before checking or cleaning the DPF muffler,
stop the engine and wait long enough until it is
cooled down.
Check to see that nothing flammable is deposited around
the DPF muffler. Otherwise a fire may result.
(1) DPF muffler