Replacement Of Radiator Hoses; Replacing Air-Conditioner Pipes And Hoses; Replacement Of Closed Breather Related Rubber Piping; Replacement Of Diesel Particulate Filter (Dpf) Differential Pressure Sensor Rubber Piping (Front And Back) - Kubota SSV65 Operator's Manual

Skid steer loader
Hide thumbs Also See for SSV65:
Table of Contents

Advertisement

80
REGULAR CHECKS AND MAINTENANCE WORK
(1) Hose
(2) Hose clamps
BReplacement of Radiator Hoses
To avoid personal injury or death:
A Replace radiator hoses and hose clamps every
two years. If the hoses are swollen, hard or
cracked, they must be replaced earlier.
(1) Radiator hose
(2) Hose clamps
BReplacing Air-Conditioner Pipes and
Hoses
To avoid personal injury or death:
A Do not touch the water hoses or the heater with
your hand. You may get burned.
Replace air-conditioner pipes and hoses every two years.
If the hoses or pipes are swollen, hard or cracked, they
should be replaced. (Consult your local KUBOTA Dealer
for this service.)
BReplacement of Closed Breather Related
Rubber Piping
Consult your local KUBOTA Dealer for this service.
BReplacement of Diesel Particulate Filter
(DPF) Differential Pressure Sensor
Rubber Piping (Front and Back)
Consult your local KUBOTA Dealer for this service.
BReplacement of Suction pipe downstream
the AFS (Air Flow Sensor)
Consult your local KUBOTA Dealer for this service.
BReplacement of Boost Sensor Pressure
Rubber Piping
Consult your local KUBOTA Dealer for this service.
BReplacement of EGR Cooler Hose
Consult your local KUBOTA Dealer for this service.

SERVICING AS REQUIRED

BChecking Amount of Refrigerant (gas)
To avoid personal injury or death:
A Liquid contact with eyes or skin may cause
frostbite.
A In the event of a leakage, wear safety goggles.
Escaping refrigerant can cause severe injuries
to eyes.
A In contact with a flame, R134a refrigerant gives
a toxic gas.
A Do
not
disconnect
refrigeration circuit of the air conditioning
system. Consult your local KUBOTA Dealer for
assistance and service.
If the air-conditioner performance is reduced, check the
following points (1)-(2).
(1) Air-conditioner condenser is clogged.
(2) Air-conditioner belt is loosened.
If there is nothing unusual with the above points, a
shortage of refrigerant is possible. Too short refrigerant
may cause a poor performance of the air-conditioner.
Consult your local KUBOTA Dealer for servicing and
replenishment.
any
part
of
the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ssv75

Table of Contents