SERVICE AS REQUIRED
(1) Fuse box with slow-blow fuse box
NOTE :
• Use the correct fuse label when replacing the
fuse cover.
(20) Fuse
(21) Fuse puller
RTV520
(A) Front
Protected circuit
Capacity
Fuse No.
(A)
1
20
2
10
3
5
4
10
5
10
6
5
7
15
8
10
9
15
10
10
11
10
12
5
13
50
14
60
15
5
16
10
17
18
15
19
20

4. Replacing slow-blow fuses

The slow-blow fuses are intended to protect the
electrical cabling. If any of them have blown out, be
sure to pinpoint the cause. Never use any substitute,
use only a Kubota genuine part.
Replacement procedure
1. Disconnect the negative cable of the battery.
2. Remove the cover and the slow-blow fuse box
cover.
3. Pull out the slow-blow fuse.
4. Insert a new slow-blow fuse into the slow-blow fuse
box.
5. Install the slow-blow fuse box cover.
6. Connect the negative battery cable.
Protected circuit
See no.13 and no.14 in the previous table.
 PERIODIC SERVICE
Protected circuit
Radiator fan motor
Cooling fan motor
Horn sw
Hazard lamp
ECU
Aux, back buzzer, combi sw
Power outlet
Brake lamp sw, meter
Work light
Head light
Meter, speed meter
Parking brake lamp, oil pressure
lamp, diagnosis lamp
Key switch
Key switch
Spare fuse
Spare fuse
Fuse puller
Spare fuse
Spare fuse
79