4. Close the drain plug and fill the radiator and the
recovery tank with coolant fluid. Let the engine idle for
about 5 min., stop the engine and remove the key.
5. Check the coolant level of recovery tank and add the
coolant if necessary.
6. The machine has been shipped filled with 50% anti-
freeze solution.
(1) Radiator cap
(2) Shutoff-valve
(1) Drain plug
(2) Coolant drain hose
(1) Coolant recovery tank
(A) "FULL"
(B) "LOW"
REGULAR CHECKS AND MAINTENANCE WORK
Radiator
Recovery tank
A Do not operate the engine without coolant.
A To fill the radiator system and the recovery tank, use
fresh water and anti-freeze fluid.
A When the anti-freeze is mixed with water, the anti-
freeze mixing ratio must be less than 50%.
A Tighten the radiator cap properly. If the cap is loose or
not properly fitted, overheating of the engine can result
due to coolant fluid loss.
BReplacing Fuel Hose
Replace the hoses and clamps.
(See "Checking Fuel and Intake Air Line" in EVERY 250
SERVICE HOURS" section.)
(1) Fuel lines
(2) Fuel drain line
BReplacing Intake Air Line
Replace the hose and clamps.
(See "Checking Fuel and Intake Air Line" in EVERY 250
SERVICE HOURS section.)