Table 2-2. Error Codes–Continued
Error
Codes
Description
6C02
DS1 BLUE ALARM:
All unframed ones signal being
received. The link cannot be used for
communication.
6C03
DS1 RED ALARM:
Incoming signal does not have valid
framing information.
Service on the link has been lost.
6C04
DS1 YELLOW ALARM:
The far end of the network interface
has lost frame synchronization.
Service on the link has been lost.
6C05
DS1 LOSS OF MULTIFRAME:
Service on the link has been lost.
6C06
DS1 REMOTE MULTIFRAME:
The far end of the network interface is
experiencing loss of multiframe.
Service on the link has been lost.
6C07
DS1 MAJOR ALARM:
Average bit error rate exceeds 10E-3.
Service on the link has been lost.
6C08
DS1 MINOR ALARM:
Average bit error rate exceeds 10E-6.
6C09
DS1 MISFRAME ALARM:
Misframe count reached 18.
Error Logs, Access Logs, and System Inventory
Action
Blue alarms are generated by intermediate
equipment, such as a CSU or DDM 1000/
2000. The far end of the network interface
may be out of service. Troubleshoot the T1
trunk, channel service unit (CSU), and the
cable between the CSU and the 100D module.
If problem persists, escalate to your technical
support organization.
Troubleshoot the T1 trunk. If problem persists,
escalate to your technical support
organization.
Troubleshoot the T1 trunk. If problem persists,
check the CSU and the DS1 configuration (the
framing format). If problem persists, escalate
to your technical support organization.
Troubleshoot the T1 trunk. If problem persists,
escalate to your technical support
organization.
Troubleshoot the T1 trunk. If problem persists,
escalate to your technical support
organization.
Troubleshoot the T1 trunk. If problem persists,
escalate to your technical support
organization.
Maintenance→Slot→Error Events→Current hr
Troubleshoot the T1 trunk. If problem persists,
escalate to your technical support
organization.
Maintenance→Slot→Error Events→Current hr
Troubleshoot the T1 trunk. If problem persists,
escalate to your technical support
organization.
Maintenance→Slot→Error Events→Current hr
Error Logs
2-11