Avaya MERLIN MAGIX Maintenance And Troubleshooting Manual page 45

Integrated system release 2.0 and earlier
Hide thumbs Also See for MERLIN MAGIX:
Table of Contents

Advertisement

Maintenance and Troubleshooting
Table 2-2. Error Codes–Continued
Error
Codes
Description
0002
POWER UP WARM START:
System programming is okay.
0003
SOFTWARE COLD START:
System programming is okay.
0004
SOFTWARE WARM START:
System programming is okay.
0005
Reset - DIAGNOSTIC SWITCH:
0006
INCOMPLETE COLD START:
System was cold-started while a restart
was in progress.
0007
SANITY TIMEOUT RESET:
Faulty software, module, carrier, or
processor sanity timer.
0008
MAX RESET COUNT EXCEEDED:
System was cold-started (System
Reset) because too many warm starts
occurred.
System programming is okay.
0009
FRIGID START:
System was restarted and initialized to
default programming.
This error is also logged after a System
Erase.
0010
INVALID SLOT INTERRUPT:
Cannot determine module responsible
for generating the interrupt.
or
The system was powered down
incorrectly, e.g. carrier 2 was powered
down before carrier 1. If errors exist
because of the improper power-down,
then no action is required.
0011
STACK OVERFLOW:
Processor problem.
Error Logs
2-4
Action
No action required; however, if problem
persists, troubleshoot the processor.
If problem persists, troubleshoot the
processor.
If problem persists, troubleshoot the
processor.
If problem persists, troubleshoot the
processor.
Troubleshoot module and or processor.
If problem persists, troubleshoot the
processor.
If the processor was removed while in use, the
system may perform a frigid start due to loss
of system programming. Restore system as
described in
''Restore''
Appendix D, "Backing up with a Memory
Card."
Troubleshoot modules and replace if
necessary. If the problem persists,
troubleshoot the processor.
Troubleshoot the processor.
on page 6-5, or in

Advertisement

Table of Contents
loading