Avaya MERLIN MAGIX Maintenance And Troubleshooting Manual page 46

Integrated system release 2.0 and earlier
Hide thumbs Also See for MERLIN MAGIX:
Table of Contents

Advertisement

Table 2-2. Error Codes–Continued
Error
Codes
Description
0012
INVALID RESET FLAG:
Processor problem.
0013
DUART STREAMING INT:
Processor problem.
or
The system was powered down
incorrectly; for example, carrier 2 was
powered down before carrier 1. If errors
exist because of the improper power-
down, no action is required.
0014
PROCESSOR ERR INTERRUPT:
Processor problem.
0015
MODULE MISMATCH:
Physical and logical type mismatch.
Module inserted into wrong slot.
0016
POWER UP COLD START:
A module dual port RAM failure was
detected.
System programming is okay.
0017
REAL TIME CLOCK FAULT:
Date and/or Time incorrect or
unreadable.
0018
RTC COLD START:
This error is not displayed.
0019
RESET TIME & DATE:
The system performs a cold start
because the real time clock chip is not
working correctly.
0C01
NO I-VMS PORT IN SERV:
This error indicates that the VMS
machine may be down.
0C02
DID INTERDIGIT TIMEOUT:
May be noisy line or central office
problem.
Error Logs, Access Logs, and System Inventory
Action
Troubleshoot the processor.
Troubleshoot the processor.
Troubleshoot the processor.
Change system programming to reflect the
proper module or install the proper module.
If problem persists, troubleshoot the module
for the slot indicated.
If this problem persists, replace the processor
module.
If this problem persists, replace the processor
module.
No action required.
No action required. If problem persists,
troubleshoot the DID line and inform the
central office if necessary.
Error Logs
2-5

Advertisement

Table of Contents
loading

Table of Contents