Avaya MERLIN MAGIX Maintenance And Troubleshooting Manual page 48

Integrated system release 2.0 and earlier
Hide thumbs Also See for MERLIN MAGIX:
Table of Contents

Advertisement

Table 2-2. Error Codes–Continued
Error
Codes
Description
0402
ABK INCORRECT CARD TYPE:
A PCMCIA card other than a
Translation card is inserted.
0403
ABK CARD WRITE-PROTECTED:
The Translation card has the write
protection switch on.
0404
ABK EXTENSION BUSY:
An extension is in program,
administration, or maintenance mode.
0405
ABK FAULTY CARD:
Unknown cause of a bad card.
0802
E911 OVERFLOW:
One of the following has occurred:
All lines assigned to E911 Partition or
Adjunct are busy or bad.
No lines are assigned to E911 Partition
or Adjunct.
No physical line is connected to the
system, the network, or the E911
Adjunct.
1C01
POOL M-BUSY EXCEEDS 50%:
More than half the trunks in the pool are
busy.
1C02
DPR TEST NOT COMPLETED:
1C03
FW UPGRADE ATTEMPT:
1C04
FW UPGRADE COMPLETE:
1C05
INVALID FMW 29 DETECTED:
Incompatibility problem. The specified
video system or data device is
connected to an 008 or 408 GS/LS
MLX with firmware vintage 0x29.
Error Logs, Access Logs, and System Inventory
Action
Remove the current card and insert a
Translation card or a card that has not been
formatted.
Flip the write protection switch on the card to
off (non-write protect mode/position.) It this
problem persists, try another card, then
replace the processor module if the problem
remains.
Wait until the extension changes mode. Make
sure the programming device (SPM or the
console) is not in programming mode when
automatic backup is scheduled to occur.
Reset card and retry. It the problem remains,
try another card. If the problem still remains,
replace the processor module.
Do the following:
Make sure the proper number of trunks are
assigned to E911 Partition or Adjunct.
Assign lines to E911 Partitions or Adjunct.
Check that ground-start or loop-start trunks
are connected to the E911 Adjunct.
Check the network interface connection.
When the condition returns to normal, the
external alarm turns off automatically. You
must remove the entry from the permanent
error log.
Troubleshoot trunk.
Slot did not complete initializing.
No action required.
No action required.
Replace the 008 or 408 MLX board with one of
another firmware vintage and retire this
permanent alarm manually.
Error Logs
2-7