Avaya MERLIN MAGIX Maintenance And Troubleshooting Manual page 167

Integrated system release 2.0 and earlier
Hide thumbs Also See for MERLIN MAGIX:
Table of Contents

Advertisement

Maintenance and Troubleshooting
Table 6-5. NI-1 BRI Provisioning Test Result Codes–Continued
Result
Code
Description
No voice hunting,
MLHV
or
Incorrect voice
MLHG DN and DN
if MLHG DN is
present, or
Voice hunting was
observed with no
MLHG DN
No data hunting, or
MLHD
Incorrect data
MLHG DN if MLHG
DN is present, or
Data hunting was
observed with no
MLHG DN
NI-1 BRI Provisioning Test
6-18
Corrective Action
The facility is correctly programmed and established with
Layers 1, 2, and 3 with functioning voice capabilities.
The possible causes of this error are:
Incoming voice calls using the MLHG DN are not
possible, but incoming voice calls using the DN are
possible. If voice hunting is expected, with the
programmed MLHG DN, check that the facility is
programmed with the MLHG DN provided by the LEC and
rerun the test. If the error persists, contact the LEC.
Incoming voice calls using either the MLHG DN or DN
are not possible, and both the MLHG DN and DN have
been verified to be incorrect. Reprogram the MLHG DN
or DN and rerun the test. If the error persists, contact the
LEC.
MLH is not expected. The MLHG DN is not programmed
and voice calls to the facility using the DN are terminated at
the facility as a hunt call. Contact the LEC.
The facility is correctly programmed and established with
Layers 1, 2, and 3 with functioning data capabilities.
The possible causes of this error are:
Incoming data calls using the MLHG DN are not
possible, but incoming data calls using the DN are
possible. If data hunting is expected, with the programmed
MLHG DN, check that the facility is programmed with the
MLHG DN provided by the LEC and rerun the test. If the
error persists, contact the LEC.
Incoming data calls using either the MLHG DN or DN
are not possible, and both the MLHG DN and DN have
been verified to be correct. Reprogram the MLHG DN or
DN and rerun the test. If the error persists, contact the LEC.
MLH is not expected. The MLHG DN is not programmed
and data calls to the facility using the DN are terminated at
the facility as a hunt call. Contact the LEC.