Table 6-5. NI-1 BRI Provisioning Test Result Codes–Continued
Result
Code
Description
LAYER 1 BRI
LAYR1
Provisioning error
on facility
LAYER 2 BRI
LAYR2
Provisioning error
on facility
LAYER 3 BRI
LAYR3
Provisioning error
on facility
Testing was not
NOTST
performed on this
facility because no
other Layer 3
initialized facility
was available in the
time allowed for
testing.
Testing was
?????
inconclusive
because the line(s)
used to test this
one had problems.
Corrective Action
Examine the wiring for the line, ensuring that all
connections have been closed. Rerun the test if a wiring
problem is identified. If the problem persists, or if there is
no wiring problem identified, swap the DSL and its
administration to another port on the board.
If the problem follows the DSL, contact the LEC.
If the problem remains on the original port, mark the port
defective and replace the 800 NI-BRI board.
Layer 1 is established. Unplug the connector and replug it
into the same port. Rerun the test. If the problem persists,
contact the LEC.
The possible causes of this problem are:
The DSL is provisioned with only one active DN (rather
than two) at the CO.
Two lines are programmed when only one line is provided
by the CO.
Check that the facilities are programmed properly and
rerun the tests if you made any corrections.
Layers 1 and 2 are established.
This result indicates that the CO does not do Layer 3
initialization. This error may not affect service, but the LEC
must be contacted.
Layers 1, 2 and 3 are established. Correct the known
problems on the other facilities and rerun the test.
Correct the known problems on other facilities and rerun
the test.
Tests
NI-1 BRI Provisioning Test
6-21