B.4 Installation Requirements
Dynamically balanced
measuring roll
that fulfills at least
Grade G-2.5 ISO 1940-1.
Self aligning bearings
Allow axial expansion
when using long rolls
and large temperature
changes are expected.
Mounting surface
must be flat within
0.1 mm (0.004 in.)
Stable foundation
If the measuring roll is driven,
always consult ABB to ensure
a solution with minimised risk
of disturbances.
a)
3BSE029380R0101 Rev C
To achieve the specified accuracy, the best possible reliability and long-term stability, install the
load cells in accordance with the requirements below.
Alignment of the load cells
mm (inches)
c)
Figure B-1. Installation Requirements
Tension Electronics PFEA111/112, User Manual
Section B.4 Installation Requirements
Correct torque for delivered screws intended
for the adapter plates is 24 Nm (18 ft.-lb).
Follow the manufacturer´s recommendation
for other screws.
228
(8.98)
b)
a) Max. 0.5 mm (0.02 in.)
b) Max. 1.0 mm (0.04 in.)
c) Max. 5 mm/m (0.06 in./ft.)
Shims may be placed
between the upper adapter
plate and the bearing housing
and between the lower adapter
plate and the foundation.
Shims must not be placed
immediately above or below
the load cell.
Web
B-3