Chapter 3 Commissioning

3.8.2 Performing Fast Setup using Wrap Gain

1
WebTension
2
FastSetUp
3
SetWebWidth
[XXXXXX]
4
SetWrapGain
[WrapGain]
5
CellsOnRoll
[2]
6
NominalLoad
[1 kN 225 lbs]
7
ZeroSet
[Yes]
8
WithNoTension
PressOkToZeroSet
9
EnterWrapGain
[XX.XX]
10
VoltageOut?
[Yes]
No
11
12
13
CurrentOut?
[Yes]
No
14
3-8
> 5
seconds
SeeManual
Yes
SetTensionAt10V
[XXXXXX] N
FilterSettings
[250 ms 1.5 Hz]
Yes
SetTensionAt20mA
[XXXXXX] N
Press
for 5 seconds to go to the fast setup menu.
Press
to start the fast setup sequence.
The menu SetWebWidth will only be available when the
selected unit is N/m, kN/m, kg/m or pli.
Default Web Width is 2m (78,740 inch).
Select WrapGain from the list with
Confirm with
.
Select the number of load cells that support the roll (2 or
Single Side A or Single Side B) from the list with
Confirm with
.
Check the nominal load on the load cell name plate.
Select nominal load from the list with
Confirm with
.
Zero set is used to compensate for load cell zero signal and
tare weight.
Zero set must be done with no tension applied to the roll.
1. Check that no load is applied on the roll.
2. Press
to zero set. "ActionDone" is shown on the
display for one second to confirm the zero setting action.
Enter the calculated wrap gain. For calculating wrap gain,
see Appendix (B, C, D, E, F or G) for installed load cell type.
Confirm with
.
Select Yes and press
Enter the tension value corresponding to 10 V.
Confirm with
.
Select filter settings (15, 30, 75, 250, 750 or 1500 ms) from
the list with
or
. Confirm with
Select Yes and press
Enter the tension value corresponding to 20 mA.
Confirm with
.
or
.
or
.
to set up the voltage output.
.
to set up the current output.