3.12 Complete Setup Sequence

3.12.1 Presentation Menu

WebTension
> 5 s
FastSetUp
Presentation-
Menu
SetObject
NominalLoad
ZeroSet
SetWrapGain
VoltageOutput
CurrentOutput
Miscellaneous
Menu
ServiceMenu

3.12.1.1 Set Language

3.12.1.2 Set Unit

3BSE029380R0101 Rev C
This section gives a step-by-step description with detailed information of all available setup
menus with related parameters, data and settings.
From FastSetUp
PresentationMenu
To SetObject
Figure 3-3. Main and Sub Menus of the Presentation Menu
Use up and down keys to select language
list.
The menu SetWebWidth will only be available when unit N/m, kN/m, kg/m or pli is selected.
The following languages are available:
English
German
Italian
French
Portuguese
Japanese
The following units can be set:
N (Newton)
kN (kiloNewton)
kg (kilogram)
lbs (US pounds)
Tension Electronics PFEA111/112, User Manual
Section 3.12 Complete Setup Sequence
SetLanguage
ZZ
SetUnit
ZZZZ
SetWebWidth
XXXXXX
SetDecimals
Z
unit
[ZZ],
[ZZZZ]
SetLanguage
[ZZ]
SetUnit
[ZZZZ]
SetWebWidth
[XXXXXX]
SetDecimals
[Z]