Tension Electronics PFEA111/112, User Manual
Chapter 4 Operation

4.7 Operator Menus

4-4
Examples of measuring values displayed:
Example 1:
Selected unit [N], Load cell nominal load 100 kN, Measured value 987654 N.
Value presented on display: 987600 N.
Example 2:
Selected unit [kN], Load cell nominal load 100 kN, Measured value 987654 N.
Value presented on display: 987.6 kN.
Examples of measuring values displayed together with the Set Decimals function:
Example 1:
Selected unit [pli], Load cell nominal load 1 kN, Measured value 46.5987 pli.
Set Decimals = 2
Value presented on display: 46.60 pli.
Example 2:
Selected unit [pli], Load cell nominal load 1 kN, Measured value 46.5987 pli.
Set Decimals = 0
Value presented on display: 47 pli.
This section describes the operator menus. The updating time for displayed values is 500 ms.
Use up
and
to switch between menus.
WebTension
Value
Tension A
Value
Tension B
Value
TensionDiff A-B
Value
Error and
warning messages
Figure 4-2. Operator Menus
3BSE029380R0101 Rev C