E.5 Mounting Alternatives, Calculating Force and Calculating Wrap Gain
E.5.1 Horizontal Mounting
+ 
= T × (cos   cos )
F
R
F
= 0 (Tare force is not measured)
RT
F
= F
Rtot
T (Tension)
Wrap gain
Wrap gain
E-4
+ 
T
F
R
Tare
= T × (cos   cos )
+ F
R
RT
=
Wrap gain
F
R
T
T
------- -
------------------------------------------
=
=
F
T
cos
cos
R
1
=
---------------------------------
cos
cos
In most cases, horizontal mounting is the most obvious
and simplest solution. The load cell should thus be
mounted horizontally when possible.