3.7 Performing Basic Settings
3.8 Performing a Fast Setup
3BSE029380R0101 Rev C
When the tension electronics has been powered on for the first time after delivery, you are asked
to SetLanguage and then to SetUnit. These two settings must be performed to be able to
proceed with the rest of the setup. Language and unit can be changed later on if desired.
1
SetLanguage
[English]
2
SetUnit
[N]
3
SetWebWidth
[XXXXXX]
4
SetDecimals
[X]
5
FastSetUp
The fast setup guides you through a minimum number of steps to set up the tension electronics.
You are asked to answer some questions and to enter desired values. These selections and
parameter settings must be made to get the tension electronics ready for measurement.
Only a limited number of selections and parameter settings are set in the fast setup. All other
parameters are set as factory default values. See
The fast setup can be made in two ways, depending on how the wrap gain is set.
The wrap gain can be set by selecting "HangWeight" or "EnterWrapGain".
•
Using Hanging Weights, see
•
Using Wrap Gain, see
Hanging Weights and Wrap Gain are explained in
Tension Electronics PFEA111/112, User Manual
Section 3.7 Performing Basic Settings
Select desired language from the list with
. English is set as default.
Confirm with
Select desired presentation unit from the list with
. N (Newton) is set as default.
and
Confirm with
The menu SetWebWidth will only be available when
the selected unit is N/m, kN/m, kg/m or pli.
Default Web Width is 2m (78,740 inch).
Select number of decimals from the list with
and
.
Confirm with
Press
to start the fast setup sequence.
See
Section
3.8.
If you want to make a complete setup, go to the
separate setup menus by pressing
See
Section 3.11.
Appendix A.4 Factory Default Settings.
Section 3.8.1.
Section 3.8.2.
Section
.
.
.
.
3.12.5.
and
3-5