Warnings And Errors Detected By The Tension Electronics; Errors; Flash Memory Error; Eeprom Memory Error - ABB PFEA 111 User Manual

Web tension systems with tension electronics
Table of Contents

Advertisement

6.8 Warnings and Errors Detected by the Tension Electronics

6.8.1 Errors

6.8.1.1 Flash Memory Error

6.8.1.2 EEPROM Memory Error

6.8.1.3 Supply Error

3BSE029380R0101 Rev C
Section 6.8 Warnings and Errors Detected by the Tension Electronics
Replace PFEA111/112.
Replace PFEA111/112.
IP 20-version (unsealed):
When the PFEA111/112 is connected to the 24 VDC power supply the voltage between
terminals X1:1 and X1:2 should be 18 - 36 V.
If the voltage is lower than 18 V:
Check the power supplies rating. Rating should be 18-36 V DC.
Check that the power supply has sufficient capacity. See power requirements in
Section 2.8.2 Power Supply Unit SD83x.
If the power supply has sufficient capacity, check cabling and cable resistance between
power supply and PFEA111/112.
If power supply and cabling are correct, the tension electronics is probably defect.
Replace PFEA111/112.
IP 65-version (NEMA 4):
Check the mains voltage connected to terminals X9:1 and X9:2.
Mains voltage must be:
85 - 264 V AC (100 V -15% to 240 V +10%)
Frequency range: 45 - 65 Hz
Tension Electronics PFEA111/112, User Manual
6-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pfea 112