Ip 20-Version (Unsealed) - ABB PFEA 111 User Manual

Web tension systems with tension electronics
Table of Contents

Advertisement

2.4.2.2 IP 20-version (Unsealed)

mm (inches)
3BSE029380R0101 Rev C
Figure 2-6. Installation Dimensions
Connect the cables to terminals according cable diagrams in Appendix (B, C, D, E, F or G)
depending on installed load cell type.
Do not connect solid conductors to terminals. Do not crimp pins to stranded
cores.
Earthing
The metal bottom of PFEA111-20 and PFEA112-20 connects to the metallic DIN-rail which
serves as the Tension Electronics earth connector.
This is to ensure a good earth connection both for internal logic and for the EMI immunity
and RF emission of the electronics.
The DIN-rail must have a good connection to the PE (Protective Earth) of the cabinet.
To achieve the best possible corrosion resistance, DIN-rails should be chromium plated, for
instance, yellow chromium treated. Use star washers with each screw used to fasten the
DIN-rail to the mounting plate.
To fasten the DIN-rail onto the mounting plate, the minimum screw diameter is 5 mm and
the maximum distance between screws is 100 mm.
Tension Electronics PFEA111/112, User Manual
Section 2.4.2 Mounting the Tension Electronics PFEA111/112
NOTE
(EN 50022-35x7,5
or equivalent)
2-7