Mounting The Tension Electronics Pfea111/112; Ip 65-Version (Nema 4) - ABB PFEA 111 User Manual

Web tension systems with tension electronics
Table of Contents

Advertisement

2.4.2 Mounting the Tension Electronics PFEA111/112

2.4.2.1 IP 65-version (NEMA 4)

3BSE029380R0101 Rev C
The electronic unit is delivered in an enclosure intended for wall mounting.
When choosing a place for installation, check that there will be space to open the enclosure lid
fully. Also check that there is enough working space in front of the enclosure.
The enclosure is fitted with cable glands (PFEA 111 five and PFEA 112 six cable glands).
Figure 2-4. Installation Dimensions for PFEA 111/112
Tension Electronics PFEA111/112, User Manual
Section 2.4.2 Mounting the Tension Electronics PFEA111/112
Note.To fulfill UL-requirements, the cable
gland for mains supply cable must be
replaced with an UL-listed metal fitting.
1 x for cable 6-12 [0.24"-0.47"]
Enclosure threaded for NPT-1/2"
2 x for cable 6-12 [0.24"-0.47"]
2 x for cable 4-8 [0.16"-0.31"]
Cable glands
PFEA 111
2-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pfea 112