Appendix F PFCL 201 - Designing the Load Cell Installation
F.7.3 Cabling for Load Cell PFCL 201CE
Movement direction of
the intermediate part
Figure F-4. Allowed Laying of Cable with Protective Hose for PFCL 201CE
Figure F-5. Not Allowed Laying of Cable with Protective Hose for PFCL 201CE
F-10
Cable with protective hose shall be mounted so that the movement of the intermediate part of
the load cell is not prevented.
mounted for load cell PFCL 201CE. If the intermediate part of the load cell is prevented in its
movement, it will shunt force and the measured force will differ from the actual.
The direction of the cable and protecting hose can be changed by unscrewing the connection
box and turning it 90-180°. Make sure that the cable between the connection box and the load
cell does not get jammed or damaged when the connection box is remounted.
Connection box
The cable with the protective hose must not be mounted so that it bends close to the connection
box, see
Figure
F-5, or is vertically directed.
Note! Bending is not allowed in the connection.
Figure F-4
shows how the cable and protective hose shall be
Cable with protective hose
NOTE!
3BSE029380R0101 Rev C