Chapter 6 Fault-tracing
6.3 Interchangeability
6.4 Necessary Equipment and Documentation
6-2
Unit
Tension Electronics
Load cells
The following items are required to perform fault-tracing and repairs:
•
Cable diagrams, see Appendix (B, C, D, E, F or G) for installed load cell type
•
Service tools
•
Torque wrench
•
Multimeter
Measures
The tension electronics PFEA111/112 is
interchangeable with a tension electronics of the
same type.
A new setup is required.
The load cells are directly interchangeable
with other load cells of the same type.
Zero setting PFEA111/112 and resetting "Maximum
Load A" or "Maximum Load B" are required after a
load cell has been replaced.
3BSE029380R0101 Rev C