Set Web Width; Set Decimals - ABB PFEA 111 User Manual

Web tension systems with tension electronics
Table of Contents

Advertisement

Tension Electronics PFEA111/112, User Manual
Chapter 3 Commissioning

3.12.1.3 Set Web Width

3.12.1.4 Set Decimals

3-12
N/m (Newton/meter)
kN/m (kiloNewton/meter)
kg/m (kilogram/meter)
pli (pounds per linear inch)
If the selected unit is N/m, kN/m, kg/m or pli, the Web Width needs to be set.
Default Web Width is 2m (78,740 inch).
The menu SetWebWidth will only be available when the selected unit is N/m, kN/m, kg/m or
pli.
Default Web Width is 2m (78,740 inch).
The format is XX.XXX if the width is entered in meter and XXXX.XX if the width is entered in
inch. Maximum Web Width is 50m (1968,5 inch)
The number of displayed decimals can be set in this menu. The number of decimals may be set
to a number between 0 - 5 depending on the load cell nominal load and presentation unit.
Set decimals function is further explained in
Section
4.6.
3BSE029380R0101 Rev C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pfea 112

Table of Contents