3.5 Menu Overview

Operator Menus
WebTension
0 N
Tension A
0 N
Tension B
0 N
TensionDiff A-B
0 N
Error and
warning messages
1)
Operator menus are described
in Section 4.7.
2)
Error and warning messages are
described in Section 6.6.
3)
Press
for 5 seconds to go to
the first of the Configuration and
Service menus.
4)
This menu appears if unit is set
to N/m, kN/m, kg/m or pli.
5)
Note! Some sub menus asking
confirmation questions are not
shown in this overview. In these
menus you have to confirm that
your settings should be
performed.
3BSE029380R0101 Rev C
Configuration and Service Menus
1)
3)
FastSetUp
> 5 s
See 3.8
PresentationMenu
See 3.12.1
SetObject
See 3.12.2
NominalLoad
ZZ kN ZZ lbs
2)
ZeroSet
See 3.12.4
SetWrapGain
See 3.12.5
VoltageOutput
See 3.12.6
CurrentOutput
See 3.12.7
MiscellaneousMenu
See 3.12.8
ServiceMenu
See 3.12.9
Tension Electronics PFEA111/112, User Manual
The fast setup can be made in two ways
depending on how the wrap gain is set.
Language, Unit, Web width
number of decimals are set in the presentation
menu.
Select standard roll (2 load cells), single side A
or single side B measurement.
Check the nominal load on the load cell name
plate. Select nominal load from the list with
or
. Confirm with
Zero set is used to compensate for load cell
5)
zero signal and tare weight.
Wrap gain can be determined by using hanging
weights or by calculating.
Set voltage output, filter and tension settings.
Set current output, filter and tension settings.
This menu is used to set profibus parameters
or to set factory default.
View maximum load and current offset settings
for load cell A and B. Reset maximum load
memory and offset. Simulation of load cell
signals.
Section 3.5 Menu Overview