Service Menu - ABB PFEA 111 User Manual

Web tension systems with tension electronics
Table of Contents

Advertisement

3.12.9 Service Menu

WebTension
> 5 s
FastSetUp
Presentation-
Menu
SetObject
NominalLoad
ZeroSet
SetWrapGain
VoltageOutput
CurrentOutput
Miscellaneous
Menu
ServiceMenu
3BSE029380R0101 Rev C
From MiscellaneousMenu
ServiceMenu
Figure 3-17. Service Menus
The service menu has parameters that can be viewed only and parameters that can be set.
Parameters that can be viewed only:
Software version number
Maximum load A
Displays maximum load since last reset
Present offset A
Displays zero offset at last zero set
Maximum load B
Displays maximum load since last reset
Present offset B
Displays zero offset at last zero set
Parameters that can be set:
Reset A
This action sets "Maximum load A" to zero.
Reset B
This action sets "Maximum load B" to zero.
Simulation
Activate/deactivate simulation function.
Tension Electronics PFEA111/112, User Manual
PFEA112
Version X.X
MaximumLoad A
[XXXXXX.X] N
PresentOffset A
XX.XX N
Reset A
MaximumLoad B
[XXXXXX.X] N
PresentOffset B
XX.XX N
Reset B
Simulation
ZZZ
Section 3.12.9 Service Menu
AreYouSure
AreYouSure
ActionDone
(shown for 1 s.)
ActionDone
(shown for 1 s.)
3-23