Command Summary; Table 3-3 Programming Commands - Xantrex ENET-XFR Operating Manual

Internal ethernet and rs-232 interface for xfr series programmable dc power supplies
Table of Contents

Advertisement

Operation

Command Summary

3–6
Use these commands to control the operation of the supply. They are
listed here in order of function such as PROGRAMMING, QUERY,
CALIBRATION, and STATUS commands. See
on page 3–9
for more detailed information about each command and its
use.

Table 3-3 Programming Commands

C o m m a n d D e s c r i p t i o n
AUXA
Selects the state of the AUXA output signal on the Pin 7 of the
user lines connector.
AUXB
Selects the state of the AUXB output signal on the Pin 8 of the
user lines connector.
CLR
Initializes the power supply to its Power ON (PON) state.
DLY
Sets a programmable time delay which is executed by the supply
before reporting fault conditions after a new output voltage or
current is specified.
GTL
Sends the supply to local mode.
FOLD
Sets foldback mode for the supply.
HOLD
Enables or disables voltage/current setting hold mode for the
supply.
IMAX
Sets an upper soft limit on the programmed output current for the
supply.
ISET
Sets the output current of the supply in amps (default) or in
milliamps.
LLO
Local Lockout. Disables the front panel LOCAL button.
OUT
Enables or disables voltage/current output for the supply.
OVSET
Sets the over voltage protection trip point for the supply in volts
(default) or in millivolts.
REN
Sets remote mode or local mode.
RST
Resets the supply to the present voltage and current settings if the
output is disabled by OVP or foldback protection.
TRG
Implements programmed voltage and current settings which had
been in hold mode.
VMAX
Sets an upper soft limit on the supply's programmed output
voltage.
VSET
Sets the output voltage of the power supply in volts (default) or in
millivolts.
"Command Reference"