Multichannel Commands Explained; Table 5-8 Rules For Multichannel Responses - Xantrex XTR 850 WATT SERIES Operating Manual

Xtr 850 watt series programmable dc power supply
Hide thumbs Also See for XTR 850 WATT SERIES:
Table of Contents

Advertisement

Multichannel Commands Explained

The use of multichannel addressing allows you to send messages to one
device, more than one device or to all devices. Any of the remote
interface types can be used to send a multichannel command through the
device that is physically connected to the PC to all the devices, provided
that all other devices are connected to via the RS-485 bus. In order to use
multichannel addressing, the setup of the wiring should be completed as
described in "Multiple Power Supply Connections to RS-485 Bus" on
page 5–15.
All SCPI commands in the XTR support the use of multichannel
addressing; however, only one device can respond to a message.
Responses will be sent according to the conditions set out in Table 5-8.

Table 5-8 Rules for Multichannel Responses

Condition
No multichannel
address used
Single multichannel
address specified
ALL or broadcast
multichannel
address specified
Multiple
multichannel
addresses specified
M370046-01
Response
Only the device selected
using the *adr or
:SYST[<address>]
:COMM[:MCH]:ADDR
commands will respond.
The device addressed in
the command will respond
regardless of if it has been
selected.
Only the device selected
using the *adr or
:SYST[<channel>]:C
OMM[:MCH]:ADDR
commands will respond. If
none of the devices have
been selected then no
response will be seen.
Only the device selected
using the *adr or
:SYST[<address>]
:COMM[:MCH]:ADDR
commands will respond. If
none of the device have
been selected then no
response will be seen.
Terminal Configuration
Example
SYSTem:VERSion?
SYSTem2:VERSion?
:SYSTem
ALL:VERSion?
or
:SYSTem0:VERSion?
SYSTem
1,2,4,5,6:VERSion?
5-23
5

Advertisement

Table of Contents
loading

Table of Contents