Siemens SINUMERIK 840D Description Of Functions page 130

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

3 Safety-Related Functions
3.9 Safety-related input/output signals (SGE/SGA)
Fig. 3-29
What is the minimum
Only a subset of the maximum number of available SGEs/SGAs is required
number of SGEs/SGAs
depending on the application.
that are needed?
3-130
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
SBH/SG deselection
SBH deselection
SG selection, bit 1
SG selection, bit 0
SE selection
Gear ratio selection, bit 2
Gear ratio selection, bit 1
SGEs
Gear ratio selection, bit 0
Test stop selection
Pulses disabled status (NCK)
SG correction selection bit 3
SG correction selection bit 2
SG correction selection bit 1
SG correction selection bit 0
ext. STOP A deselection
ext. STOP C deselection
ext. STOP D deselection
SBH/SG active
Axis safely referenced
SN1 -
SN2 -
SGAs
SN3 -
SN4 -
SN1 +
SN3 +
SN2 +
SN4 +
n < n
1)
x
SG active bit 1
840D from SW4.2
1)
SG active bit 0
840D from SW 4.4.18
2)
SBH active
1)
Enable pulses (NCK) or
Pulses are disabled status (drive)
SGEs and SGAs in each monitoring channel for each axis/spindle
Note
The SGE/SGA signals are described in Chapter 4, "Description of Interface
Signals".
Note
SGEs that are not needed must be set to a defined signal status.
In the NCK monitoring channel:
By presetting the assigned machine data to appropriate values
(e.g. input is permanently set to 0 (default) or 1)
In the drive monitoring channel:
By appropriately programming the interface signals in the PLC user program.
1)
1)
1)
1)
2)
2)
2)
1)
1)
© Siemens AG 2003 All Rights Reserved
11.03
SBH/SG
SE
SN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 digital

Table of Contents