7 Configuring example
7.3 Safety Integrated with SPL
7.3.12
Appendix
Excerpt from symbol table:
Symbol
1
Hochlauf_ASUP_Start
2
Flanke_FB4_SPL_Start
3
Zyklus_FB4_SPL_Start
4
FB4_Start
5
FC9_SPL_Start
6
Teststop_aktiv
7
Teststop_1_starten
8
Teststop_1_ready
9
Teststop_2_starten
10 Teststop_2_ready
11 Teststop_2_error
12 Teststop_1_error
13 QUIT_NCK_error
14 Teststopphase_2_starten
15 Test_Stop_D_PLC
16 Test_Stop_C_PLC
17 Test_Stop_A_PLC
18 PLC_Stop_A_nicht_aktiv
19 Test_Stop_D_NCK
20 Test_Stop_C_NCK
21 Test_Stop_A_NCK
22 NCK_Stop_A_nicht_aktiv
23 Test_I/O_Peripherie_1
24 Test_I/O_Peripherie_2
25 Test_I/O_Peripherie_3
26 Test_I/O_Peripherie_4
27 Test_I/O_Peripherie_5
28 Fehler_Stop_D_PLC
29 Teststop_1_intern
30 Teststop_2_intern
31 QUIT_NCK_error_code
32 TIMER1
33 TIMER2
34 T_K_ABFALL
35 T_VERZUG_1
36 T_VERZUG_2
37 Teststop_Zeit_1
38 Teststop_Zeit_2
39
Teststop_Zeit_3
7-410
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
Address
Data type
Comment
M 210.0
BOOL
Run-up marker for SPL / ASUB start
M 210.1
BOOL
Edge marker for SPL / FB4 start
M 210.2
BOOL
Cycle marker for SPL / FB4 start
M 210.3
BOOL
Interrupt number and polarity for SPL (FB4)
M 210.4
BOOL
Start SPL
M 211.0
BOOL
Activate test stop
M 211.1
BOOL
Forced checking procedure of the shutdown paths (X, C)
M 211.2
BOOL
Test stop1 performed without errors
M 211.3
BOOL
Forced checking procedure of shutdown paths (Z)
M 211.4
BOOL
Test stop 2 performed without errors
M 211.6
BOOL
Error for test stop 2 (Z)
M 211.7
BOOL
Error for test stop 1 (X, C)
M 214.4
BOOL
Error for transfer using FC21
M 216.0
BOOL
Start test of external stops
M 216.1
BOOL
Trigger stop D in PLC / FC96
M 216.2
BOOL
Trigger stop C in PLC / FC96
M 216.3
BOOL
Trigger stop A in PLC / FC96
M 216.4
BOOL
Stop A / PLC check not active
M 216.5
BOOL
Trigger stop D via A 49.4 / PLC in NCK
M 216.6
BOOL
Trigger stop C via A 49.3 / PLC in NCK
M 216.7
BOOL
Trigger stop A via A 49.2 / PLC in NCK
M 217.0
BOOL
Stop A / NCK check not active
M 217.1
BOOL
Forced checking procedure of the I/O devices
M 218.0
BOOL
Check Emergency Stop inputs
M 218.1
BOOL
Start acknowledgement for Emergency Stop
M 218.2
BOOL
Acknowledge Emergency Stop on the NCK side
M 218.3
BOOL
Withdraw acknowledgment Emergency Stop on the
NCK side
M 218.7
BOOL
Checkback input of contactors E 76.4 not OK.
MD 212
DWORD
Run test stop 1 FC60 internally
MD 220
DWORD
Run test stop 2 FC60 internally
MW
188
WORD
Error code from FC21
T 20
TIMER
STOP C -> STOP A (axes)
T 21
TIMER
STOP C-> STOP A (spindle)
T 22
TIMER
Drop-out time of contactors K1, K2
T 23
TIMER
Delay time EMERGENCY STOP input
T 24
TIMER
Delay time, acknowledgment
T 30
TIMER
Monitoring duration 2h 40min
T 31
TIMER
Monitoring duration 5h 20min
T 32
TIMER
Monitoring duration 8h