Siemens SINUMERIK 840D Description Of Functions page 279

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

11.03
Step 9
All standard monitoring functions (e.g. zero-speed monitor, software limit
Re-activate standard
switches) that were de-activated or altered for the purpose of the acceptance
monitoring functions
test must now be re-activated/returned to original settings.
Save machine data.
Step 10
Save machine data
!
Step 11
Delete password .
Delete password
To delete the password, go to the screen "Start-up\Machine configuration" and
select the vertical softkey labeled PASSWORD...\DELETE PASSWORD.
5.1.3
Series commissioning
The settings for the safety monitoring functions are automatically transferred
with other data in the course of a normal series commissioning process. The
following steps need to be taken in addition to the normal commissioning
procedure:
1.
2.
Sequence of
The following sequence of operations makes sense when commissioning series
operations for series
equipment:
commissioning
© Siemens AG 2003 All Rights Reserved
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
Use the SERVICES\DATA OUTPUT softkeys to save all machine data to
an external computer or the hard disk in the MMC. This data can be used
to commission series equipment.
In order to carry-out series commissioning, the machine data of the NCK
and drive must be available as separate data sets (the softkey COPY SI
DATA may not be used for the purpose of commissioning series
equipment).
Caution
On completion of the acceptance text, all illegal (old) MD files must be
removed from the hard disk (to avoid confusion between old and new data).
The data that corresponds to the acceptance test data must be backed-up
(archived).
Enter a user agreement
Carry-out an acceptance test
(individual monitoring functions must be randomly tested).
Note
When series machines are commissioned, two separate data sets for the
drive and NCK must be downloaded into the control system. The copy
function may be used after machine data have been altered.
Download the data set for the series machine (separate sets for NCK and
drive) into the control system.
Adjust the absolute encoder
Carry out a POWER ON.
This ensures that any errors, i.e. deviations in data content that may exist
between the NCK and drive will be detected by the checksum check and
crosswise data comparison.
5 Commissioning
5.1 Commissioning SINUMERIK 840D
5-279

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 digital

Table of Contents