$MA_SAFE_VELO_STATUS_OUTPUT[n]
MD number
Output assignment, SG active
Default: 0
Change becomes effective after POWER ON:
Data type: DWORD
Meaning
This data determines the outputs or system variables for the "SG active bit 0" and "SG
active bit 1" signals.
Structure: Refer to coding of output assignment
n = 1, 0
SG active
Bit 1
= 0
= 1
= 0
= 1
Special cases, errors
36984
$MA_SAFE_EXT_PULSE_ENAB_OUTPUT
MD number
Assignment of output terminal for selection of "external pulse enable"
Default: 0
Change becomes effective after RESTART
Data type: DWORD
Meaning
This MD must be parameterized as soon as the internal pulse cancellation is used (bit 30
in $MA_SAFE_PULSE_ENABLE_OUTPUT=1)
Structure: Refer to coding of input assignment
With each machine data of this kind, a single I/O bit is connected to a terminal or a system
variable. Otherwise, the structure of the machine data is as for 36970 and onwards.
Special cases, errors
References
36985
$MA_SAFE_VELO_X_STATUS_OUTPUT
MD number
Output assignment for n < n
Default: 0
Change becomes effective after POWER ON:
Data type: DWORD
Meaning
This data determines the output or system variable for the "n < n
Structure: Refer to coding of output assignment
Signal
= 0
= 1
Corresponds with ...
$MA_SAFE_VELO_X
Special cases, errors
© Siemens AG 2003 All Rights Reserved
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
Min. input value: 0
Protection level (R/W) 7/2
Applies from SW 4.2
stands for SG active, bits 1, 0
Bit 0
means
= 0
SG1 active if SBH/SG is active and SBH is not active
SBH active if SBH/SG and SBH are active
= 0
SG2 active
= 1
SG3 active
= 1
SG4 active
If a single output signal is connected to a terminal, the following applies:
If MD bit 31 is set, then the signal is processed inverted (ss = 81)
If several output signals are connected to the same terminal, the following applies:
If MD bit 31 is set (ss = 81), the relevant signal is initially inverted.
The (in some cases inverted) output signals are then ANDed and the result output at
the terminal.
Min. input value: 0
Protection level (R/W) 7/2
Applies from SW 6.3
x
Min. input value: 0
Protection level (R/W) 7/2
Applies from SW 4.2
means
Actual speed is higher than the limit speed in $MA_SAFE_VELO_X
Actual speed is lower or equal to the limit speed
If a single output signal is connected to a terminal, the following applies:
If MD bit 31 is set, then the signal is processed inverted (ss = 81)
If several output signals are connected to the same terminal, the following applies:
If MD bit 31 is set (ss = 81), the relevant signal is initially inverted.
The (in some cases inverted) output signals are then ANDed and the result output at
the terminal.
4 Data Descriptions
4.1 Machine data
840D
Max. input value: -
Unit: -
840D
Max. input value: 0x811E0810
Unit: -
840D
Max. input value:
Unit:
" signal.