4 Data Descriptions
4.1 Machine data
Additional parameterization for local inputs on the NCU (from SW 6.3.21):
s = 0
s = 1
s = 4
36970
$MA_SAFE_SVSS_DISABLE_INPUT
MD number
Input assignment, SBH/SG de-selection
Default: 0
Change becomes effective after POWER ON:
Data type: DWORD
Meaning
This data defines the NCK input for selection/de-selection of the SBH and SG functions.
Signal
= 0
Design:
= 1
Special cases, errors
References
/FB/, A4, Digital and Analog NCK I/Os
Corresponds with...
MD 10366: $MN_HW_ASSIGN_DIG_FASTIN
MD 13010: $MN_DRIVE_LOGIC_NR
36971
$MA_SAFE_SS_DISABLE_INPUT
MD number
Input assignment, SBH de-selection
Default: 0
Change becomes effective after POWER ON:
Data type: DWORD
Meaning
Assignment of the NCK input for de-selecting the safe operating stop function.
Design: See coding of input assignment
Assignment of terminal signal level to the safe functions if safely-reduced speed or safe
operating stop has been activated.
Signal
= 0
= 1
(only if STOP C, D or E has not been activated by other functions)
Special cases, errors
References
MD 36970: $MA_SAFE_SVSS_DISABLE_INPUT
4-230
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
Local inputs on the NCU
I/Os on the 611 digital bus
System variable assignment, internal image in the
system memory
Parameterization for s = 0 for axial SGEs:
mm
=00H
xx
=00H
nn
=01H – 04H
Min. input value: 0
Protection level (R/W) 7/2
Applies from SW 3.4
means
SG or SBH is selected
SG and SBH are de-selected
Input value "0" means:
There is no assignment, the input remains at 0, SG and SBH cannot be de-selected.
Input value "80 00 00 00" means:
There is no assignment, the input remains at 1
If MD bit 31 is set, then the signal is processed inverted (ss = 81)
Min. input value: 0
Protection level (R/W) 7/2
Applies from SW 3.4
means
Safe operating stop is selected
Safely-reduced speed is selected
If MD bit 31 is set, then the signal is processed inverted (ss = 81)
This input is of no significance if SG and SBH have been de-selected (see
$MA_SAFE_SVSS_DISABLE_INPUT).
fixed
fixed
Bit number
Max. input value: -
Unit: -
Max. input value: -
Unit: -
© Siemens AG 2003 All Rights Reserved