11.03
Test stop step 2
FC97 program excerpt
//Forced checking procedure of the external STOPs A ,C and D
//
//
//
//
//
//
//
//
//
//
//
//
//
© Siemens AG 2003 All Rights Reserved
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
U
M
216.0
// Start test stop step 2
UN
DB31.DBX
108.2 // Axis X Pulses not safely cancelled
UN
DB32.DBX
108.2 // Axis Z pulses not safely cancelled
UN
DB33.DBX
108.2 // Spindle C pulses not safely cancelled
S
M 216.1
// Initiate Stop D on PLC FC96
R
M 216.0
// Reset Start test stop step 2
U
M 216.1
// Check Stop D on the PLC side
U
DB31.DBX
111.6 // STOP D active Axis X
U
DB32.DBX
111.6 // STOP D active Axis Z
U
DB33.DBX
111.6 // STOP D active Spindle C
S
M
216.2
// Initiate Stop C on the PLC side FC96
R
M
216.1
// Reset Check Stop D PLC
U
M
216.2
// Check Stop C on the PLC side
U
DB31.DBX
111.5 // STOP C active Axis X
U
DB32.DBX
111.5 // STOP C active axis Z
U
DB33.DBX
111.5 // STOP C active Spindle C
S
M
216.3
// Initiate Stop A on the PLC side FC96
R
M
216.2
// Reset Check Stop C PLC
U
M
216.3
// Check Stop A on the PLC side
U
DB31.DBX
111.4 // STOP A/B active Axis X
U
DB32.DBX
111.4 // STOP A/B active Axis Z
U
DB33.DBX
111.4 // STOP A/B active Spindle C
S
M
216.4
// Check: STOP A (PLC) not active
R
M
216.3
// Reset Check Stop A PLC
U
M
216.4
// Check: STOP A (PLC) not active
UN
DB31.DBX
111.4 // STOP A/B active Axis X
UN
DB32.DBX
111.4 // STOP A/B active Axis Z
UN
DB33.DBX
111.4 // STOP A/B not active Spindle C
S
M
216.5
// Initiate Stop D on the NCK side
R
M
216.4
// Reset Check STOP A PLC
U
M
216.5
// Initiate Stop D on the NCK side
=
A
49.4
// See circuit diagram and NCK-SPL
U
M
216.5
// Check Stop D on the NCK side
U
DB31.DBX
111.6 // STOP D active Axis X
U
DB32.DBX
111.6 // STOP D active Axis Z
U
DB33.DBX
111.6 // STOP D active Spindle C
S
M
216.6
// Initiate Stop C on the NCK side
R
M
216.5
// Reset Check Stop D NCK
U
M
216.6
// Initiate Stop C on the NCK side
=
A
49.3
// See circuit diagram and NCK-SPL
U
M
216.6
// Check Stop C on the NCK side
U
DB31.DBX
111.5 // STOP C active Axis X
U
DB32.DBX
111.5 // STOP C active axis Z
U
DB33.DBX
111.5 // STOP C active Spindle C
S
M
216.7
// Initiate Stop A on the NCK side
R
M
216.6
// Reset Check Stop C NCK
U
M
216.7;
// Initiate Stop A on the NCK side
=
A
49.2;
// See circuit diagram and NCK-SPL
U
M
216.7
// Check Stop A on the NCK side
U
DB31.DBX
111.4 // STOP A/B active Axis X
U
DB32.DBX
111.4 // STOP A/B active Axis Z
U
DB33.DBX
111.4 // STOP A/B active Spindle C
S
M
217.0
// Check: STOP A (NCK) not active
R
M
216.7
// Reset Check Stop A NCK
U
M
217.0
// Check: STOP A (NCK) not active//
UN
DB31.DBX
111.4 // STOP A/B active Axis X
UN
DB32.DBX
111.4 // STOP A/B active Axis Z
UN
DB33.DBX
111.4 // STOP A/B not active Spindle C
S
M
217.1
// Start forced checking procedure at
R
M
217.0
// Reset check: STOP A NCK