7 Configuring example
7.6 SI I/Os using fail-safe modules connected to PROFIBUS DP
Components of the node IM151 HF: F-DI module
The diagram below shows the parameter settings for the F-DI module:
(8) IM 151-1 HF
Baugruppe
PM-E DC24V
4/8 F-DI DC24V
4 F-DO DC24V/2A
PM-E F DC24V/10A 2 F-DO
4 DO 24V/10A
Eigenschaften - 4/8 F-DI DC24V - (R-/S5)
Allgemein
Adressen
Parameter
Parameter
F-Parameter
F_Quell_Adresse
F_Ziel_Adresse
DIL-Schalterstellung (9........0)
F_Überwachungszeit (ms)
Baugruppenparameter
Eingangsverzögerung
Kurzschlusstest
Kanal 0, 4
Kanal 1, 5
Kanal 2, 6
Kanal 3, 7
OK
Fig. 7-35
Parameter settings for the F-DI module
Explanationen of
The parameters of the F-DO module are explained below:
parameters
7-430
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
Bestellnummer
E-Adre..... A-Adres.... D..... Kommentar
6ES7 138-4CA00-0AA0
6ES7 138-4FA00-0AB0
128...133
6ES7 138-4FB00-0AA0
134...138
6ES7 138-4CF00-0AB0
139...143
6ES7 132-4BD30-0AA0
Parameter
Wert
1: SI PLC315-2DP 2AF03
1022
1111111110
100
Aktiviert
Auswertung der Geber
2v2-Auswertung
Art der Geberverschaltung
Zweikanalsensor
Diskrepanzzeit (ms)
300
Aktiviert
Auswertung der Geber
2v2-Auswertung
Art der Geberverschaltung
Antivalentsensor
Diskrepanzzeit (ms)
300
F_Source_Address
The parameter F_Source_Address is automatically assigned for the
configured F master (in this case, the NCU 572.4 or NCU 573.4). This
parameter is identical for all PROFIsafe components since they are
associated with the same PROFIsafe master.
F_Target_Address
The parameter F_Target_Address is automatically assigned for the
relevant F module and displayed in the decimal notation (for the F-DI
module 1022). The DIL switch setting displayed must be set accordingly.
This address is needed later for parameterizing the machine data in the
hexadecimal notation (for the F-DI module 3FE).
F_Monitoring time
The parameter F_Monitoring time defines the maximum time within which a
new valid F telegram must have been received from the F master.
Generally, the default value can be used.
128...131
F-Zieladresse 1111111110 (hexadezimal 3FE)
134...138
F-Zieladresse 1111111101 (hexadezimal 3FD)
139...143
F-Zieladresse 1111111100 (hexadezimal 3FC)
32.0...32.3
Abbrechen
Hilfe
© Siemens AG 2003 All Rights Reserved