Siemens SINUMERIK 840D Description Of Functions page 299

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

11.03
This extended alarm text is based on the interaction between the NCK system
software (that specifies the parameter that addresses the supplementary
information for the alarm text) and the HMI software (that has to appropriately
process this parameter).
Dedicated extended alarm texts can be defined for the following Safety
Integrated system alarms:
Prerequisites, HMI
The following entry is located in the configuration file for the alarm server (file
Advanced
MBDDE.INI) in the section [Text files].
File excerpt: mbdde.ini
[Textfiles]
NCK=f:\dh\mb.dir\aln_
This means that all of the NCK alarms are defined in the file referenced after
the NCK entry. The processing of an extended alarm text for the above
specified alarms is prepared as part of this definition
File excerpt: aln_gr.com
027090 0 0 "Error for crosswise data comparison NCK-PLC,
%1[%2], NCK: %3; %4<ALSI>"
027254 0 0 "PROFIsafe: F module %1, error in channel %2;
%3<ALSI>"
An extended alarm text can be defined for an alarm using the supplement
%4<ALSI> (Alarm 27090) and %3<ALSI> (Alarm 27254). If required, this entry
can be subsequently entered into older HMI software versions, in order to
activate the display of the extended alarm text – under the assumption that the
NCK system software supports this.
Principle of operation
If Alarm 27090 or Alarm 27254 occurs, the NCK transfers an additional
– extended alarm text
parameter value (27090:%4; 27254: %3) to the HMI software. This parameter
has a defined value range. Each value can be uniquely assigned an extended
alarm text.
Value range of the transfer parameter
000
001...064
© Siemens AG 2003 All Rights Reserved
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
General SPL crosswise data comparison error (different status of the
SPL variables)
Alarm 27090, error for crosswise data comparison NCK-PLC
extended alarm text is available from NCU system software 05.03.25 and
06.03.01.
Channel-related error on the PROFIsafe module (only when using the
PROFIsafe I/O
Alarm 27254 PROFIsafe: F module, error in the channel
Extended alarm text available from NCU system software 06.04.15
Parameterizing error detected at run-up (different state active)
Crosswise data comparison error, SPL protective mechanism:
MD 11500 – DB18.DBX36.0
Crosswise data comparison error, stop response for SPL error:
MD 10097 – DB18.DBX36.1
Error in system variables $A_INSE(P)[01...64] (Alarm 27090/
Alarm 27254)
If the safety-related input signal is taken from a PROFIsafe
module, then only a safe signal state is transferred to the NCK
and PLC. This means that internally, a different state no longer
5 Commissioning
; Example : Standard entry
5.5 Diagnostics