11.03
Necessity of an
A full acceptance test (as described in this Chapter) must always be carried-out
acceptance test
when the functionality of Safety Integrated is commissioned for the first time on
a machine.
Extended safety-relevant functionality, transferring the commissioned software
to additional series machines, modifications to the hardware, software
upgrades etc. may make it necessary to carry-out the acceptance test with a
reduced test scope. The conditions prescribing the necessity for, or giving
suggestions for the required test scope are given below.
Overview/definitions
In order to define a partial acceptance test it is first necessary to describe the
for performing the
individual parts of the acceptance test and then define logical groups that
acceptance test
represent the components of the acceptance text.
Contents of the full
DOCUMENTATION
acceptance test
Documentation of the machine incl. safety functions
1.
2.
3.
4.
5.
6.
FUNCTION TEST PART 1
General function check incl. checking the wiring/programming
7.
8.
9.
10. Test the crosswise data comparison of the basic Safety Integrated
11. Test the EMERGENCY STOP function and the safety circuits
12. Test the changeover of SI functions.
FUNCTION TEST PART 2
Detailed function test incl. checking the values of the individually used SI
functions
13. Test the SI function "safely-reduced speed" – SG
14. Test the SI function "safe operating stop" – SBH
15. Test the SI function "safe software limits" – SE
© Siemens AG 2003 All Rights Reserved
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
Machine description (with overview)
Details about the control system
Configuration plan
Function table
Active monitoring functions depending on the operating mode, the
protective doors and other sensors
Ideally, this table should be the object and result of the configuring work.
SI functions per axis
Information about the safety equipment.
Test the shutdown paths path
(test the forced checking procedure of the shutdown paths)
Test the external stops
Test the forced checking procedure of the inputs and outputs
functions and Safety Integrated SPL system variables
(in each case with evaluated measurement diagram and measured values)
(in each case with evaluated measurement diagram and measured values)
(in each case with evaluated measurement diagram and measured values)
5 Commissioning
5.2 Acceptance report