Siemens SINUMERIK 840D Description Of Functions page 163

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

11.03
3.10 Safe programable logic (SPL) (840D SW 4.4.18)
SPL status signals
for DB18.DBW136
DB18.DBX136.0
SPL_STATUS[1]
DB18.DBX136.1
SPL_STATUS[2]
DB18.DBX136.2
SPL_STATUS[3]
DB18.DBX136.3
SPL_STATUS[4]
DB18.DBX136.4
SPL_STATUS[5]
DB18.DBX136.5
SPL_STATUS[6]
DB18.DBX136.6
SPL_STATUS[7]
DB18.DBX136.7
SPL_STATUS[8]
DB18.DBX137.0
SPL_STATUS[9]
DB18.DBX137.1
SPL_STATUS[10]
DB18.DBX137.2
SPL_STATUS[11]
DB18.DBX137.3
SPL_STATUS[12]
DB18.DBX137.4
SPL_STATUS[13]
DB18.DBX137.5
SPL_STATUS[14]
DB18.DBX137.6
SPL_STATUS[15]
DB18.DBX137.7
SPL_STATUS[16]
Table 3-61
Overview of DB 18 signals
DB18
Signal
r Read
w-Write
Parameterization part
INSEP_VALID[1..8]
r/w
OUTSEP_VALID[1..8]
r/w
INSEP_ADDR[1..8]
r/w
OUTSEP_ADDR[1..8]
r/w
SPL_READY
r/w
STOP E
Data area/status
SPL_DATA
INSEP[1..64]
r
OUTSEP[1..64]
r/w
INSIP[1..64]
r
OUTSIP[1..64]
r/w
MARKERSIP[1..64]
r/w
SPL_DELTA
INSEP[1..64]
r
OUTSEP[1..64]
r
INSIP[1..64]
r
OUTSIP[1..64]
r
MARKERSIP[1..64]
r
CMDSI
r/w
© Siemens AG 2003 All Rights Reserved
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
NCK-PLC interface parameterized
NCK-PLC program file exists
NCK waits until the PLC has run-up
NCK-PLC in cyclic mode
Call FB4 processing for SPL
End FB4 processing on NCK
Call FC9 processing for SPL
End FC9 processing on NCK
SPL started via PROG_EVENT mechanism (from SW 6.4.15)
Crosswise data comparison NCK started
Crosswise data comparison PLC started
NCK-SPL checksum checking active
All SPL protective mechanisms active (from SW 6.4.15)
End of SPL program reached
Not assigned
Not assigned
Type
Value range
Remarks
Bool
0 = INSEP[1..8] No automatic transfer, can be
supplied by the user program
1 = Transfer of input byte defined in
INSEP_ADDR[1..8] to INSEP[1..8] by basic
program
Bool
0 = OUTSEP[1..8] No automatic transfer, can
be retrieved by the user program
1 = Transfer to output byte defined in
OUTSEP[1..8] from OUTSET_ADDR[1..8] by
the basic program
Int
1..EB Max
Address input byte
Int
1..AB Max
Address output byte
Bool
0 = Commissioning phase
(no STOP D is triggered for crosswise data
comparison error)
1 = Commissioning completed
(STOP D/E is triggered for crosswise data
comparison error)
If DB18, DBX36.1 = 1 was set, and if a
crosswise data comparison error is
determined, then an external STOP E instead
of an external STOP D is transferred to the
drive
Useful data:
Bool
External PLC input for SPL
Bool
External PLC output for SPL
Bool
Internal PLC input for SPL
Bool
Internal PLC output for SPL
Bool
Marker for SPL
Signal differences for diagnostics:
Bool
External PLC input for SPL
Bool
External PLC output for SPL
Bool
Internal PLC input for SPL
Bool
Internal PLC output for SPL
Bool
Marker for SPL
Bool
Timeout value in crosswise data comparison
is extended by a factor of 10
3 Safety-Related Functions
3-163