Siemens SINUMERIK 840D Description Of Functions page 251

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

11.03
This function is only active when MD 36961 and MD 1361 are set to 5. If a
value not equal to 5 is entered, then the parameterized stop response from MD
1361 is valid and 1363 is not evaluated.
1370
$MD_SAFE_TEST_MODE
SI acceptance test mode
Unit:
Default:
-
0
Corresponds to the BTSS variables safeAcceptTestMode for NCK – signals the
request for an acceptance test mode:
0:
0xAC:
1371
$MD_SAFE_TEST_STATE
Acceptance test status
Unit:
Default:
-
0
Corresponds to the BTSS variables safeAcceptTestState for the NCK – signals
the state of the drive regarding the acceptance test mode:
0:
0xC:
0xD:
0xF:
0xAC:
1380
$MD_SAFE_PULSE_DIS_TIME_FAIL
Time up to pulse cancellation
Unit:
Default:
ms
0
After the drive bus fails, the pulses must have been safely cancelled after this
time has expired.
1390
$MD_SAFE_FIRMWARE_VERSION
Firmware version SINUMERIK Safety Integrated
Unit:
Default:
-
-
The machine data is assigned each time the machine tool is powered up –
irrespective of whether SINUMERIK Safety Integrated
When a separate version ID for SI is displayed, the certification costs with the
German Statutory Industrial Accident Insurance Association (BIA) are reduced
as only software releases have to be registered that include changes.
© Siemens AG 2003 All Rights Reserved
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
4.2 Machine data for SIMODRIVE 611 digital
Minimum value:
Maximum value:
0
0xAC
Request, exit the acceptance test mode, error acknowledgement
Request, go into the acceptance test mode
Minimum value:
Maximum value:
0
0xAC
Acceptance test mode inactive
At least 1 active SI POWER ON alarm present when the system
goes into the acceptance test mode
Incorrect ID received in MD 1370
Acceptance timer has expired
Acceptance test mode is active
Minimum value:
Maximum value:
0
800
Minimum value:
Maximum value:
-
-
4 Data Descriptions
611 digital
Relevant for:
840D
FD/MSD
from SW 6.4.15
Data type:
Becomes
short integer
effective:
Immediate
611 digital
Relevant for:
840D from SW4.2
FD/MSD
Data type:
Becomes
short integer
effective:
ImmediateE
611 digital
Relevant for:
840D from SW4.2
FD/MSD
Data type:
Becomes
float
effective:
Restart
611 digital
Relevant for:
SW: 4.02/07
FD/MSD
Data type:
Becomes
long integer
effective:
Immediate
is selected or not.
4-251

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: