Siemens SINUMERIK 840D Description Of Functions page 357

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

11.03
Activating
The function is activated via MD 10094
$MN_SAFE_ALARM_SUPPRESS_LEVEL. The function is already active when
standard data is loaded. This means that the alarms are displayed with a
reduced scope. Alarms 27000 and 300950 can be replaced by Alarm 27100
using MD 10094.
Limitation
The MD is not included in the axial safety MD checksum. This means that the
function can be enabled/disabled at any time by changing the MD. During the
acceptance test, the alarm suppression function should be disabled in order to
be able to check the two-channel error detection. After the acceptance test it
can be re-enabled to reduce the number of alarms displayed to the final user.
© Siemens AG 2003 All Rights Reserved
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
27030-300743: Configuring error. Only occurs in systems that contain 611
digital control modules that are not safety-related.
27033: MD parameterizing errors displayed on the NCK side are covered
on the drive side by the Alarms 300745-300747, 301706-301708.
27090, 27091, 27092, 27093, 27095: These SPL monitoring alarms are not
implemented on the drive side.
300748, 300749, 300776: These drive-side monitoring functions are not
implemented on the NCK side.
300745, 300746, 300747, 301706, 301707, 301708: These monitoring
functions are displayed by the NCK using Alarm 27033 with reference to
the associated MD.
6 Alarms