5 Commissioning
5.2 Acceptance report
5.2 Acceptance report
The machine manufacturer must perform an acceptance test of the activated SI
functions on the machine. This test must provoke that all of the limit values are
violated for the enabled SI functions to ensure that they are operating correctly.
Authorized person,
All SI functions must be acceptance-tested by an authorized person and the
acceptance report
test results recorded in a test report. The report must be signed by the person
who carried-out the acceptance tests. The acceptance test report must be kept
in the logbook of the particular machine.
After the SPL has been commissioned the access rights for the NCK-SPL
(SAFE.SPF) via the HMI interface must be reduced to the manufacturer or
service level and documented in the acceptance report.
Authorization in the above sense is a person authorized by the machine
manufacturer who on account of his or her technical qualifications and
knowledge of the safety functions has the necessary skill sets to perform the
acceptance test in the correct manner.
5-282
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
Note
Some of the standard NC monitoring functions, such as zero speed
monitoring, software limit switches, etc. must be de-activated (monitoring
limits must be made less sensitive) before the acceptance test is carried out.
The function sequences can be acquired and listed using the servo trace
function (840D, from SW 4.2 onwards) or using the D/A converter output.
References /IAD/, SINUMERIK 840D Installation & Start-Up Guide
Note
If the machine data of SI functions are changed, a new acceptance test must
be carried-out for the modified SI function and recorded in the acceptance
report.
Note
Please refer to the information in Chapter 5, "Commissioning for
SINUMERIK 840D".
The acceptance report presented below is both an example and
recommendation. The specified values apply to the system chosen for
this particular example.
Template for the acceptance report:
An electronic template for the acceptance report is available:
– in the toolbox for SINUMERIK 840D
– on DOCONCD for SINUMERIK 840D
– on the service CD for SINUMERIK 840
The acceptance report comprises checking the alarm displays and
including the alarm reports in the overall acceptance report. In order to
obtain reproducible and comparable alarm displays, during the
acceptance test, MD 10094: $MN_SAFE_ALARM_SUPPRESS_LEVEL
must be set to 0 in order to avoid suppressing alarm outputs.