Pwr-Power; Ral-Remote Access Level - Christie Boxer 30 Technical Reference

Serial api commands
Hide thumbs Also See for Boxer 30:
Table of Contents

Advertisement

PWR–Power
Changes the power state of the product.
If the housekeeping board suffers a failure while the projector is on, the projector remains on with
fans running until AC power is removed. The (PWR0) command fails while the projector is in this state.
Commands
Command
Description
PWR?
Returns the current power state of the projector.
(Read-only)
PWR <0 | 1>
Turns the projector on or off.
PWR+ELEC <0 | 1>
Keeps video electronics on in standby, regardless
of lamp state.
Examples
Return the power setting for the projector:
(PWR?)
(PWR!000 "Power Off")
Turn off the projector:
(PWR 0)
Turn on the projector:
(PWR 1)
RAL–Remote Access Level
Sets the default remote serial protocol access level for any of the serial ports.
Commands
Command
Description
RAL <value>
Sets the access level on all Ethernet port.
(Saved value)
RAL+PRTA <value>
Sets the access level for the RS232 port.
(Saved value)
Boxer 30 Technical Reference–Serial API Commands
020-102096-08 Rev. 1 (08-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
Serial API commands
Values
000 = Standby
001 = On
010 = Cooling down
011 = Warming up
0 = Turns the projector off
1 = Turns the projector on
0 = Disables electronics override
1 = Enables electronics override
Values
0 = No Access—Disables the port
1 = Login Required—Sets read-only access
until a separate login is performed
2 = Free Access—Executes commands at
the operator level unless a separate login is
performed (Default)
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Boxer 2k

Table of Contents