Installation and Setup Guide 020-102866-01 CP2308-G...
Page 2
The warranty does not apply to any product where the serial number has been removed or obliterated. The warranty also does not apply to any product sold by a reseller to an end user outside of the country where the reseller is located unless (i) Christie has an office in the country where the end user is located or (ii) the required international warranty fee has been paid.
Learn about the safety precautions related to the Christie CP2308-G projector. Disclaimer statement The CP2308-G subassembly is not a functional product. Hazard labels must be placed on the end product. The end product must meet the regulatory compliance requirements for China.
• SHOCK HAZARD! A dedicated, protected ground or earth wire must be installed on the product by Christie qualified technicians or electricians before it can be connected to power. • SHOCK HAZARD! Only use the AC power cord provided with the product or recommended by Christie.
Learn about the labels that may be used on the product. Labels on your product may be yellow or black and white. General hazards Hazard warnings also apply to accessories once they are installed in a Christie product that is connected to power. Fire and Shock Hazard To prevent fire or shock hazards, do not expose this product to rain or moisture.
Safety precautions Explosive material hazard. To avoid personal injury, disconnect all power sources before performing maintenance or service, and wear Christie-approved protective clothing. Bright light hazard. To avoid personal injury, never look directly at the light source. Pinch hazard. To avoid personal injury, keep hands clear and loose clothing tied back.
Introduction This manual is intended for professionally trained operators of Christie high-brightness CP2308-G projection systems. For complete production documentation and technical support, go to www.christiedigital.com. Projector components - front Learn about the components on the front of the projector. Touch panel...
2. Extend or retract the feet. 3. When the adjustment is correct, tighten the lock nut. Stacking projectors To stack CP2308-G projectors, use the stacking kit provided. The stacking kit includes these parts: Locking bracket (quantity 4) Stacking cup (quantity 4) M6 screw (quantity 4) When stacking projectors, the optical axis of the projectors must be parallel to one another.
• SHOCK HAZARD! A dedicated, protected ground or earth wire must be installed on the product by Christie qualified technicians or electricians before it can be connected to power. • SHOCK HAZARD! Only use the AC power cord provided with the product or recommended by Christie.
• FIPS—The LED is green when the FIPS (Federal Information Processing Standards Publications) security status is operating correctly. If the LED is red, an error has occurred. Restart the Christie IMB. If the LED remains red, return the Christie IMB to Christie Digital Systems USA Inc.
2. To communicate with the projector, add the projector to the same network as the computer. Connecting devices to the 3D sync terminal For information on connecting devices to the 3D sync terminal, see the CP2308-G User Manual. CP2308-G Installation and Setup Guide 020-102866-01 Rev.
When adjusting boresight, you must maintain the boresight distance from the lens to the prism plane set by Christie. For example, when you move the top screw outward, turn the bottom two boresight screws to maintain the overall distance.
Caution! If not avoided, the following could result in minor or moderate injury. • This procedure must be performed by Christie qualified technicians. Typically, horizontal boresight does not require adjustment. It should only be adjusted if a large horizontal angular offset to the screen is required.
Page 27
Adjusting the image When adjusting boresight, you must maintain the boresight distance from the lens to the prism plane set by Christie. For example, when you move the top screw outward, turn the bottom two boresight screws to maintain the overall distance.
Normally, the three colors should overlap precisely to form pure white lines throughout the image and one or more poorly converged individual colors may appear adjacent to some or all of the lines. Contact your Christie accredited service technician to correct DMD convergence issues. Adjusting the fold mirror Learn how to align the fold mirror with the optical system to correct an image with missing or shadowy corners or edges.
Learn how to create Measured Color Gamut Data (MCGD) files to correct on-screen colors. Using a colorimeter, measure the colors displayed on the screen from the center of the audience viewing location. For more information, see the CP2308-G User Manual. CP2308-G Installation and Setup Guide 020-102866-01 Rev.
Page 32
Corporate offi ces Worldwide offi ces Christie Digital Systems USA, Inc. Australia Germany Republic of South Africa United Kingdom Cypress ph: +61 (0) 7 3624 4888 ph: +49 2161 664540 ph: +27 (0)11 510 0094 ph: +44 (0) 118 977 8000...