Rbt-Reboot; Sdi-Sdi Payload Overrride - Christie Boxer 30 Technical Reference

Serial api commands
Hide thumbs Also See for Boxer 30:
Table of Contents

Advertisement

Examples
Set port to Login Required:
(RAL+PRTA 1)
RBT–Reboot
Reboots the projector.
This command only works if the projector is in standby mode.
Commands
Command
Description
RBT 111
Reboots the projector. To prevent accidental
use of this command, the number 111 must
follow this command.
Examples
Reboot the projector:
(RBT 111)
SDI–SDI Payload Overrride
Overrides the SMPTE 352M payload for HBMIC-SDI inputs.
This setting applies to all HBMIC-SDI inputs in the system (such as, not per input).
Commands
Command
Description
SDI <value>
Changes the HBMIC-SDI payload override
setting. This command is only available if
the video electronics are on. (Saved value)
SDI+PAYL "<custom
Defines the customized SMPTE 352M
string>"
payload as a 4-byte hex string when the
SDI command is set to custom. For more
details, contact Christie Technical Support.
Boxer 30 Technical Reference–Serial API Commands
020-102096-08 Rev. 1 (08-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
Serial API commands
Values
111
Values
0 = Auto Detect (Default)
1 = Custom
2 = 3G-A 1080p60
3 = 3G-A 1080p59.94
4 = 3G-A 1080p50
5 = 3G-A 2K60
6 = 3G-A 2K59.94
7 = 3G-A 2K50
custom string = 4-byte hex string in big-
endian order:
"<b0><b1><b2><b3>"
52